Specifications - Model 73201/R
Display | 4300-count digital reading |
DC Voltage Accuracy1 | 0.75% + 1 |
AC Voltage Accuracy2 | 1% + 5 |
Additional Functions | Auto hold, overvoltage and current warning |
Features |
|
Operating Temp and Humidity | 0 to 50°C; 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
Power Supply | Two AAA (LR03 or R03) dry cells |
Battery Life | Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) |
Dimensions | 74 (W) x 155 (H) x 31 (D) mm |
Weight | Approx. 240 g (including batteries) |
Compliance with Standards | Safety EN61010-1 (1995) + Amend; EN61010-2-031 (1995) (600 V, CAT II; 300 V, CAT III; contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997) |
Standard Accessories | AAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1 |
Optional Accessories | Carrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007) |
1 40V - 600V Range
2 4V - 600V Range
Specifications - Model 73202/R
Display | 4300-count digital reading |
DC Voltage Accuracy1 | 0.5% + 1 |
AC Voltage Accuracy2 | 1% + 5 |
Additional Functions | Auto hold, overvoltage and current warning |
Features |
|
Operating Temp and Humidity | 0 to 50°C; 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
Power Supply | Two AAA (LR03 or R03) dry cells |
Battery Life | Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) |
Dimensions | 74 (W) x 155 (H) x 31 (D) mm |
Weight | Approx. 240 g (including batteries) |
Compliance with Standards | Safety EN61010-1 (1995) + Amend; EN61010-2-031 (1995) (600 V, CAT II; 300 V, CAT III; contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997) |
Standard Accessories | AAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1 |
Optional Accessories | Carrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007) |
1 40V - 600V Range
2 4V - 600V Range
Specifications - Model 73203/R
Display | 4300-count digital reading |
DC Voltage Accuracy1 | 0.5% + 1 |
AC Voltage Accuracy2 | 0.75% + 1 |
Additional Functions | Auto hold, overvoltage and current warning |
Features |
|
Operating Temp and Humidity | 0 to 50°C; 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
Power Supply | Two AAA (LR03 or R03) dry cells |
Battery Life | Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) |
Dimensions | 74 (W) x 155 (H) x 31 (D) mm |
Weight | Approx. 240 g (including batteries) |
Compliance with Standards | Safety EN61010-1 (1995) + Amend; EN61010-2-031 (1995) (600 V, CAT II; 300 V, CAT III; contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997) |
Standard Accessories | AAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1 |
Optional Accessories | Carrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007) |
1 40V - 600V Range
2 4V - 600V Range
Specifications - Model 73204/R
Display | 4300-count digital reading |
DC Voltage Accuracy1 | 0.3% + 1 |
AC Voltage Accuracy2 | 0.75% + 1 |
Additional Functions | Auto hold, overvoltage and current warning |
Features |
|
Operating Temp and Humidity | 0 to 50°C; 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
Power Supply | Two AAA (LR03 or R03) dry cells |
Battery Life | Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) |
Dimensions | 74 (W) x 155 (H) x 31 (D) mm |
Weight | Approx. 240 g (including batteries) |
Compliance with Standards | Safety EN61010-1 (1995) + Amend; EN61010-2-031 (1995) (600 V, CAT II; 300 V, CAT III; contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997) |
Standard Accessories | AAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1 |
Optional Accessories | Carrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007) |